900 kVA class
Baudouin generator
12M26G900/5
Compare UK-built 820 kVA diesel generators and nearby outputs. View open and canopied models, exact prime and standby ratings, and datasheets. Get a quote.
A rounded PPG model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
12M26G900/5
12M26G900/5
4006-23TAG2A
4006-23TAG2A
2806A-E18TTAG5
2806A-E18TTAG5
4006-23TAG2A
4006-23TAG2A
12M26G900/5
12M26G900/5
QSK23G3
QSK23G3
6M33G825/5
6M33G825/5
12M26G825/5
12M26G825/5
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 820 kVA corresponds to 656 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleThe model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with PPG.
The comparison above includes Baudouin, Cummins, Perkins. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| PPG900BS | Baudouin | Acoustic canopied | 820 kVA | 904 kVA | 400 V |
| PPG900B | Baudouin | Open set | 820 kVA | 904 kVA | 400 V |
| PPG820PS | Perkins | Acoustic canopied | 743 kVA | 816 kVA | 400 V |
| PPG820P | Perkins | Open set | 743 kVA | 816 kVA | 400 V |
| PPG830PS | Perkins | Acoustic canopied | 750 kVA | 825 kVA | 400 V |
| PPG830P | Perkins | Open set | 750 kVA | 825 kVA | 400 V |
| PPG810PS | Perkins | Acoustic canopied | 741 kVA | 814 kVA | 400 V |
| PPG810P | Perkins | Open set | 741 kVA | 814 kVA | 400 V |
| PPG910BS | Baudouin | Acoustic canopied | 828 kVA | 907 kVA | 400 V |
| PPG910B | Baudouin | Open set | 828 kVA | 907 kVA | 400 V |
| PPG880CS | Cummins | Acoustic canopied | 812 kVA | 880 kVA | 400 V |
| PPG880C | Cummins | Open set | 812 kVA | 880 kVA | 400 V |
| PPG830BS | Baudouin | Acoustic canopied | 772 kVA | 829 kVA | 400 V |
| PPG830B | Baudouin | Open set | 772 kVA | 829 kVA | 400 V |
| PPG810BS | Baudouin | Acoustic canopied | 730 kVA | 805 kVA | 400 V |
| PPG810B | Baudouin | Open set | 730 kVA | 805 kVA | 400 V |
Tell us your load, site and application. We’ll help you choose the right configuration.