410 kVA class
Perkins generator
2206A-E13TAG2
Compare UK-built 410 kVA diesel generators and nearby outputs. View open and canopied models, exact prime and standby ratings, and datasheets. Get a quote.
A rounded PPG model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
2206A-E13TAG2
2206A-E13TAG2
DC13071A-02-02
QSZ13G6
QSZ13G6
2206A-E13TAG3
2206A-E13TAG3
2206A-E13TAG3
2206A-E13TAG3
6M21G2D0/S
6M21G2D0/S
DC13072A-02-11
2206A-E13TAG2
2206A-E13TAG2
6M21G440/5
6M21G440/5
For larger commercial sites and industrial equipment, assess the largest load step, motor starting, nonlinear loads and the operating duty. The steady-state kVA total alone does not settle the generator size.
At a power factor of 0.8, 410 kVA corresponds to 328 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleThe model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with PPG.
The comparison above includes Baudouin, Cummins, Perkins, Scania. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| PPG410PS | Perkins | Acoustic canopied | 361 kVA | 412 kVA | 400 V |
| PPG410P | Perkins | Open set | 361 kVA | 412 kVA | 400 V |
| PPG410SS | Scania | Acoustic canopied | 412 kVA | Confirm on enquiry | 400 V |
| PPG410CS | Cummins | Acoustic canopied | 360 kVA | 407 kVA | 400 V |
| PPG410C | Cummins | Open set | 360 kVA | 407 kVA | 400 V |
| PPG450PS | Perkins | Acoustic canopied | 406 kVA | 450 kVA | 400 V |
| PPG460PS | Perkins | Acoustic canopied | 406 kVA | 454 kVA | 400 V |
| PPG450P | Perkins | Open set | 406 kVA | 450 kVA | 400 V |
| PPG460P | Perkins | Open set | 406 kVA | 454 kVA | 400 V |
| PPG420BS | Baudouin | Acoustic canopied | 360 kVA | 415 kVA | 400 V |
| PPG420B | Baudouin | Open set | 360 kVA | 415 kVA | 400 V |
| PPG410S | Scania | Open set | 360 kVA | 405 kVA | 400 V |
| PPG400PS | Perkins | Acoustic canopied | 356 kVA | 403 kVA | 400 V |
| PPG400P | Perkins | Open set | 356 kVA | 403 kVA | 400 V |
| PPG440BS | Baudouin | Acoustic canopied | 402 kVA | 442 kVA | 400 V |
| PPG440B | Baudouin | Open set | 402 kVA | 442 kVA | 400 V |
Tell us your load, site and application. We’ll help you choose the right configuration.