700 kVA class
Cummins generator
VTA28G5
Compare UK-built 690 kVA diesel generators and nearby outputs. View open and canopied models, exact prime and standby ratings, and datasheets. Get a quote.
A rounded PPG model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
VTA28G5
VTA28G5
VTA28G5
VTA28G5
2806A-E18TAG4
2806A-E18TAG4
2806A-E18TAG4
2806A-E18TAG4
DC16093A-02-53
DC16093A-02-53
DC16093A-02-53
DC16093A-02-53
DC16078A-02-43
DC16078A-02-43
2806A-E18TAG2
2806A-E18TAG2
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 690 kVA corresponds to 552 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleThe model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with PPG.
The comparison above includes Cummins, Perkins, Scania. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| PPG700CS | Cummins | Acoustic canopied | 640 kVA | 691 kVA | 400 V |
| PPG700C | Cummins | Open set | 640 kVA | 691 kVA | 400 V |
| PPG690CS | Cummins | Acoustic canopied | 640 kVA | 692 kVA | 400 V |
| PPG690C | Cummins | Open set | 640 kVA | 692 kVA | 400 V |
| PPG770PS | Perkins | Acoustic canopied | 700 kVA | 770 kVA | 400 V |
| PPG770P | Perkins | Open set | 700 kVA | 770 kVA | 400 V |
| PPG780PS | Perkins | Acoustic canopied | 704 kVA | 774 kVA | 400 V |
| PPG780P | Perkins | Open set | 704 kVA | 774 kVA | 400 V |
| PPG670SS | Scania | Acoustic canopied | 613 kVA | 674 kVA | 400 V |
| PPG670S | Scania | Open set | 613 kVA | 674 kVA | 400 V |
| PPG680SS | Scania | Acoustic canopied | 613 kVA | 673 kVA | 400 V |
| PPG680S | Scania | Open set | 613 kVA | 673 kVA | 400 V |
| PPG780SS | Scania | Acoustic canopied | 708 kVA | 776 kVA | 400 V |
| PPG780S | Scania | Open set | 708 kVA | 776 kVA | 400 V |
| PPG720PS | Perkins | Acoustic canopied | 670 kVA | 721 kVA | 400 V |
| PPG720P | Perkins | Open set | 670 kVA | 720 kVA | 400 V |