690 kVA class
Cummins generator
VTA28G5
A model-specific render and installation drawing will be supplied with the quotation.
Designed and manufacturedOpen set generator with a VTA28G5 engine and Stamford S5L1D-F41 reference alternator. Open sets require a suitable installation with ventilation, exhaust and weather protection.
Exact ratings above: 400 V, 3-phase, 50 Hz reference configuration. The model number is a rounded class.
Price and lead time confirmed with your quotation.
| PPG model | PPG690C |
|---|---|
| Engine brand / model | Cummins VTA28G5 |
| Alternator | Stamford S5L1D-F41 |
| Frequency | 50 Hz |
| Reference voltage | 400 V |
| Reference phase | 3 phase |
| Exact prime rating | 640 kVA / 512 kW |
| Exact standby rating | 692 kVA / 554 kW |
| Aspiration | Turbocharged |
|---|---|
| Governor | Electronic |
| No. of Cylinders | 12 |
| Cylinder Arrangement | At Vee |
| Displacement | 28L |
| Cooling Type | Liquid Cooled |
| Coolant Capacity | 159L |
| Oil Capacity | 83L |
| Type | Brushless |
| Poles | 4 |
| AVR Model | AS440 |
| Voltage Regulation | 1.0% Regulation% |
| Insulation Class | H |
| Excitation | Brushless |
Ratings for the reference engine and alternator configuration. Confirm the required connection and voltage with your quotation.
| Voltage | ESP kVA | ESP kW | PRP kVA | PRP kW |
|---|---|---|---|---|
| 380 V | 689 kVA | 551 kW | 638 kVA | 510 kW |
| 400 V | 692 kVA | 554 kW | 640 kVA | 512 kW |
| 415 V | 693 kVA | 554 kW | 640 kVA | 512 kW |
These documented electrical combinations sit within this rounded model family. Final enclosure and component selection are agreed with your quotation.
| Engine | Alternator | Phase | Voltage | Prime / PRP | Standby / ESP |
|---|---|---|---|---|---|
| VTA28G5 | Stamford S5L1D-F41 | 3 | 400 V | 640 kVA | 692 kVA |
| VTA28G5 | Leroy Somer TAL0473F | 3 | 400 V | 640 kVA | 693 kVA |
| Reference weight | 2050 kg |
|---|---|
| Reference fuel tank | 730 litres |
| Configuration market | Export |
Dimensions and weight relate to the stated reference build, not every option. Acoustic figures, where listed, are manufacturer references at 75% rated kW using distance corrections. Confirm the project noise requirement and final drawing before installation.
| 50% Load | 73 litres/hour |
|---|---|
| 75% Load | 104 litres/hour |
| 100% Load | 140 litres/hour |
| 110% Load | 154 litres/hour |
Manufacturer reference consumption. Actual fuel use depends on load, operating conditions and the final specification.
VTA28G5
VTA28G5
VTA28G5
Tell us your load, site and application. We’ll help you choose the right configuration.