830 kVA class
Perkins generator
2806A-E18TTAG5
Compare UK-built 750 kVA diesel generators and nearby outputs. View open and canopied models, exact prime and standby ratings, and datasheets. Get a quote.
A rounded PPG model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
2806A-E18TTAG5
2806A-E18TTAG5
4006-23TAG2A
4006-23TAG2A
4006-23TAG2A
4006-23TAG2A
2806A-E18TTAG5
2806A-E18TTAG5
2806A-E18TTAG5
2806A-E18TTAG5
12M26G825/5
12M26G825/5
2806A-E18TAG4
2806A-E18TAG4
6M33G825/5
6M33G825/5
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 750 kVA corresponds to 600 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleThe model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with PPG.
The comparison above includes Baudouin, Perkins. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| PPG830PS | Perkins | Acoustic canopied | 750 kVA | 825 kVA | 400 V |
| PPG830P | Perkins | Open set | 750 kVA | 825 kVA | 400 V |
| PPG820PS | Perkins | Acoustic canopied | 743 kVA | 816 kVA | 400 V |
| PPG820P | Perkins | Open set | 743 kVA | 816 kVA | 400 V |
| PPG810PS | Perkins | Acoustic canopied | 741 kVA | 814 kVA | 400 V |
| PPG810P | Perkins | Open set | 741 kVA | 814 kVA | 400 V |
| PPG840PS | Perkins | Acoustic canopied | 765 kVA | 843 kVA | 400 V |
| PPG840P | Perkins | Open set | 765 kVA | 843 kVA | 400 V |
| PPG850PS | Perkins | Acoustic canopied | 767 kVA | 846 kVA | 400 V |
| PPG850P | Perkins | Open set | 767 kVA | 846 kVA | 400 V |
| PPG810BS | Baudouin | Acoustic canopied | 730 kVA | 805 kVA | 400 V |
| PPG810B | Baudouin | Open set | 730 kVA | 805 kVA | 400 V |
| PPG770PS | Perkins | Acoustic canopied | 700 kVA | 770 kVA | 400 V |
| PPG770P | Perkins | Open set | 700 kVA | 770 kVA | 400 V |
| PPG830BS | Baudouin | Acoustic canopied | 772 kVA | 829 kVA | 400 V |
| PPG830B | Baudouin | Open set | 772 kVA | 829 kVA | 400 V |