890 kVA class
Perkins generator
4006-23TAG3A
Compare UK-built 890 kVA diesel generators and nearby outputs. View open and canopied models, exact prime and standby ratings, and datasheets. Get a quote.
A rounded PPG model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
4006-23TAG3A
4006-23TAG3A
4006-23TAG3A
4006-23TAG3A
QSK23G3
QSK23G3
12M26G900/5
12M26G900/5
12M26G900/5
12M26G900/5
4008TAG1A
4008TAG1A
4006-23TAG3A
4006-23TAG3A
KTA38G3
KTA38G3
Consider installation access, load steps, future expansion and the control interface alongside the rating. Synchronisation, changeover and acoustic requirements need a project-specific specification.
At a power factor of 0.8, 890 kVA corresponds to 712 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleThe model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with PPG.
The comparison above includes Baudouin, Cummins, Perkins. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| PPG890PS | Perkins | Acoustic canopied | 799 kVA | 893 kVA | 400 V |
| PPG890P | Perkins | Open set | 799 kVA | 893 kVA | 400 V |
| PPG900PS | Perkins | Acoustic canopied | 802 kVA | 896 kVA | 400 V |
| PPG900P | Perkins | Open set | 802 kVA | 896 kVA | 400 V |
| PPG880CS | Cummins | Acoustic canopied | 812 kVA | 880 kVA | 400 V |
| PPG880C | Cummins | Open set | 812 kVA | 880 kVA | 400 V |
| PPG900BS | Baudouin | Acoustic canopied | 820 kVA | 904 kVA | 400 V |
| PPG900B | Baudouin | Open set | 820 kVA | 904 kVA | 400 V |
| PPG910BS | Baudouin | Acoustic canopied | 828 kVA | 907 kVA | 400 V |
| PPG910B | Baudouin | Open set | 828 kVA | 907 kVA | 400 V |
| PPG1000PS | Perkins | Acoustic canopied | 911 kVA | 1000 kVA | 400 V |
| PPG1000P | Perkins | Open set | 911 kVA | 1000 kVA | 400 V |
| PPG860PS | Perkins | Acoustic canopied | 797 kVA | 860 kVA | 400 V |
| PPG860P | Perkins | Open set | 797 kVA | 860 kVA | 400 V |
| PPG1000CS | Cummins | Acoustic canopied | 931 kVA | 1010 kVA | 400 V |
| PPG1000C | Cummins | Open set | 931 kVA | 1010 kVA | 400 V |
Tell us your load, site and application. We’ll help you choose the right configuration.