280 kVA class
Baudouin generator
6M16G6D0/S
Compare UK-built 275 kVA diesel generators and nearby outputs. View open and canopied models, exact prime and standby ratings, and datasheets. Get a quote.
A rounded PPG model class is not a guaranteed duty rating. The tables below identify the actual documented output for each reference configuration.
6M16G6D0/S
6M16G6D0/S
QSL9G3
QSL9G3
1206A-E70TTAG3
1206A-E70TTAG3
DC09320A-02-62
DC09320A-02-62
1206A-E70TTAG3
1206A-E70TTAG3
DC09072A-02-12
DC09072A-02-12
1506A-E88TAG4
1506A-E88TAG4
6M16G4D0/S
6M16G4D0/S
For larger commercial sites and industrial equipment, assess the largest load step, motor starting, nonlinear loads and the operating duty. The steady-state kVA total alone does not settle the generator size.
At a power factor of 0.8, 275 kVA corresponds to 220 kW mathematically. That conversion is not a substitute for the manufacturer’s duty rating or a starting-load assessment.
Discuss your load scheduleThe model class alone does not establish continuous capability. Check prime and standby ratings and the manufacturer’s load-profile conditions. Confirm the intended run hours and average load when requesting a quotation.
Compare the canopied entries above, then confirm enclosure dimensions, sound requirements and final duty rating with PPG.
The comparison above includes Baudouin, Cummins, Perkins, Scania. Some are close alternatives rather than an exact match; use the electrical rating table to compare them.
| Model | Engine brand | Format | Prime | Standby | Voltage |
|---|---|---|---|---|---|
| PPG280BS | Baudouin | Acoustic canopied | 250 kVA | 275 kVA | 400 V |
| PPG280B | Baudouin | Open set | 250 kVA | 275 kVA | 400 V |
| PPG280CS | Cummins | Acoustic canopied | 250 kVA | 275 kVA | 400 V |
| PPG280C | Cummins | Open set | 250 kVA | 275 kVA | 400 V |
| PPG280PS | Perkins | Acoustic canopied | 250 kVA | 275 kVA | 400 V |
| PPG280P | Perkins | Open set | 250 kVA | 275 kVA | 400 V |
| PPG280SS | Scania | Acoustic canopied | 276 kVA | Confirm on enquiry | 400 V |
| PPG280S | Scania | Open set | 276 kVA | Confirm on enquiry | 400 V |
| PPG270PS | Perkins | Acoustic canopied | 248 kVA | 270 kVA | 400 V |
| PPG270P | Perkins | Open set | 248 kVA | 270 kVA | 400 V |
| PPG310SS | Scania | Acoustic canopied | 281 kVA | 308 kVA | 400 V |
| PPG310S | Scania | Open set | 281 kVA | 308 kVA | 400 V |
| PPG310PS | Perkins | Acoustic canopied | 283 kVA | 308 kVA | 400 V |
| PPG310P | Perkins | Open set | 283 kVA | 308 kVA | 400 V |
| PPG260BS | Baudouin | Acoustic canopied | 235 kVA | 259 kVA | 400 V |
| PPG260B | Baudouin | Open set | 235 kVA | 259 kVA | 400 V |
Tell us your load, site and application. We’ll help you choose the right configuration.